InteliDrive DCU Marine - 3.0.0 Global Guide
245
Related FW 3.0.0 Related applications All
Comm object 68
Description
AI influences directly Engine Values: Speed Request register when configured without ramp. In the case of
sensor fail (out of range) is Speed request = 0,0% for PRP and 50,0% (=Nominal RPM) for AUX. There is
expected range of values 0,0 100,0% for this Logical Analog input.
See Engine Values: Speed Request charts for (page 267) and (page 267) modes.
Requested RPM
6 back to List of LAI
Related FW 3.0.0 Related applications PRP
Comm object 69
Description
Actual engine torque in %, received from J1939.
Engine Torque (PRP only)
6 back to List of LAI
Related FW 3.0.0 Related applications All
Comm object 82
Description
There are two cumulative Statistics registers - values TripCons and DayCons. Those statistic values
increment value based on sampling of Logical Analog Input Fuel ConsAct. LAI can be sourced from ECU
Fuel Rate [l/h ] or separate Actual Fuel consumption sensor connected to physical Analog input.
Both statistics values is possible to modify in InteliMonitor Set Statistics command or clear by Logical
Binary Inputs ClearDayCons or ClearTripCons.
Fuel ConsAct
6 back to List of LAI

Table of Contents