InteliDrive DCU Marine - 3.0.0 Global Guide
132
Setpoint group Engine params Related FW 3.0.0
Range [units] 0,0 .. 100,0 [%/s]
Default value 5
Step 0,1
Comm object 9984 Related applications All
Config level Standard
Setpoint visibility Always
Description
Speed ramp setting for BI Speed Up / Down, not for Analog input request.
BI Speed Ramp
6 back to List of setpoints
Setpoint group Engine params Related FW 3.0.0
Range [units] 0,0 .. 100,0 [%]
Default value 50,0
Step 0,1 % of Requested RPM range.
Comm object 10008 Related applications PRP
Config level Standard
Setpoint visibility Always
Description
When Binary input Fire Speed is closed the binary output Clutch Connect opens (this action deactivates
loadsharing mode if it was activated before) and Loadsharing: ThrottlePos is set to Engine params:
FireAlarmSpeed value.
FireAlarmSpeed
6 back to List of setpoints
Setpoint group Engine params Related FW 3.0.0
Range [units] [ENABLED, DISABLED]
Default value DISABLED
Step [-]
Comm object 10098 Related applications All
Config level Standard
Setpoint visibility Always
Description
ENABLED: Engine Values: Speed Request is defined by Engine params: Local speed setpoint that can
be modified by Fast edit function from front panel (4 sec Enter, / ¯, Enter).
DISABLED: Engine Values: Speed Request is changed via Binary inputs Speed Up, Speed Down or via
Logical Analog input Requested RPM.see
Speed Request (page 266) t charts for (page 267) and (page 267) modes.
EnLocalSpeed
6 back to List of setpoints