InteliDrive DCU Marine - 3.0.0 Global Guide
155
Setpoint group Load sharing Related FW 3.0.0
Range [units] 0,0 .. ClutchMaxSpeed [%]
Default value 0,0
Step 0,1
Comm object 10096 Related applications PRP
Config level Standard
Setpoint visibility Always
Description
Clutch can be switched on if ClutchMinSpeed < RPM < ClutchMaxSpeed. Limits are in % of the
Requested speed. See Requested RPM, Overload protection (PRP only) (page 27)
Note: 0,0% corresponds to (Idle speed + Idle offset) value, 100,0% corresponds to Nominal speed.
ClutchMinSpeed
6 back to List of setpoints
Setpoint group Load sharing Related FW 3.0.0
Range [units] ClutchMinSpeed .. 100,0 [%]
Default value 100,0
Step 0,1
Comm object 10097 Related applications PRP
Config level Standard
Setpoint visibility Always
Description
Clutch can be switched on if ClutchMinSpeed < RPM < ClutchMaxSpeed. Limits are in % of Requested
speed. See Requested RPM, Overload protection (PRP only) (page 27)
Note: 0,0% corresponds to (Idle speed + Idle offset) value, 100,0% corresponds to Nominal speed.
ClutchMaxSpeed