InteliDrive DCU Marine - 3.0.0 Global Guide
140
Setpoint group Engine protect Related FW 3.0.0
Range [units] 0 .. 60 [s]
Default value 0
Step 1
Comm object 10571 Related applications All
Config level Standard
Setpoint visibility Always
Description
Delay for Force block protection activation after binary input Force Block 3 is opened. Protection
deactivation is without delay. Protection is activated/deactivated independent on engine running or not
running state.
ForceBlockDel3
6 back to List of setpoints
Setpoint group Engine protect Related FW 3.0.0
Range [units] 0 .. 200 [%]
Default value 110
Step 1% of Nominal RPM
Comm object 8263 Related applications All
Config level Standard
Setpoint visibility Always
Description
Threshold for engine overspeed protection.
Overspeed
6 back to List of setpoints