Comm object 173
Description
PrestartOvrd skips the Prestart procedure timing and continues to Cranking. The same effect has repeated
press of Start button.
Example: Finish engine preheating (prelubrication) based on temperature (pressure) limit.
PrestartOvrd
6 back to List of LBI
Related FW 3.0.0 Related applications PRP
Comm object 182
Description
ClutchBlocking can block the LBO Clutch Connect. Active input is indicated in Alarm list as “Clutch
Blocking” message.
ClutchBlocking
6 back to List of LBI
Related FW 3.0.0 Related applications All
Comm object 200
Description
Input simulates the panel ← Mode button
ModeL Button
6 back to List of LBI
Related FW 3.0.0 Related applications All
Comm object 201
Description
Input simulates the panel Mode → button.
ModeR Button
6 back to List of LBI
Related FW 3.0.0 Related applications All
Comm object 202
Description
Input simulates the panel Page button.
Page Button