EasyManua.ls Logo

ComAp InteliDrive DCU Marine - ID-SCM Unit; Freqrate1; Freqrate2; Transferrate1

ComAp InteliDrive DCU Marine
285 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
InteliDrive DCU Marine - 3.0.0 Global Guide
170
ID-SCM unit
This setpoints are available when the SCM module is configured in DriveConfig / Modules window.
Not possible to use ID-SCM when ID-RPU is used.
Setpoint group SCM unit Related FW 3.0.0
Range [units] 0 .. 500 [-]
Default value 0
Step 1
Comm object 10902 Related applications All
Config level Standard
Setpoint visibility Always
Description
Conversion constant (number of pulses for one RPM) for ID-SCM RPM1 frequency input - SCM Freq1
value. Frequency range max. 8 kHz.
FreqRate1
6 back to List of setpoints
Setpoint group SCM unit Related FW 3.0.0
Range [units] 0 .. 500 [-]
Default value 0
Step 1
Comm object 10903 Related applications All
Config level Standard
Setpoint visibility Always
Description
Conversion constant (number of pulses for one RPM) for ID-SCM RPM2 frequency input - SCM Freq2
value. Frequency range max. 8 kHz.
FreqRate2
6 back to List of setpoints
Setpoint group SCM unit Related FW 3.0.0
Range [units] 0 .. 500 [-]
Default value 0
Step 1
Comm object 10906 Related applications All
Config level Standard
Setpoint visibility Always
Description
Conversion ratio (number of pulses for increase by 1) for ID-SCM IMP 1 impulse input / SCM Imp1 value.
Frequency range max. 60 Hz.
TransferRate1
6 back to List of setpoints

Table of Contents

Other manuals for ComAp InteliDrive DCU Marine

Related product manuals