InteliDrive DCU Marine - 3.0.0 Global Guide
127
Setpoint group Engine params Related FW 3.0.0
Range [units] 0,0 .. 100,0 [%]
Default value 0,0
Step 0,1
Comm object 10010 Related applications PRP
Config level Standard
Setpoint visibility Always
Description
Offset of Idle speed in % of RPM difference between nominal and idle setpoints (Nominal RPM Idle RPM)
see Requested RPM, Overload protection (PRP only) on page 27
Note: 100% of Engine Values: Requested Speed is the range between Engine params: Idle RPM
and Basic setting: Nominal RPM.
Idle Offset
6 back to List of setpoints
Setpoint group Engine params Related FW 3.0.0
Range [units] 0 .. 600 [s]
Default value 10
Step 1
Comm object 9097 Related applications All
Config level Standard
Setpoint visibility Always
Description
Idle time delay starts when RPM exceeds Starting RPM.
During the Idle time the Binary output Idle/Nominal is opened and after then it is closed. Binary output
Idle/Nominal opens during Cooling period (Cooling Time) again.
Idle Time
6 back to List of setpoints