EasyManua.ls Logo

ComAp InteliDrive DCU Marine - Configuration Examples; Sensors Availability

ComAp InteliDrive DCU Marine
285 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
InteliDrive DCU Marine - 3.0.0 Global Guide
64
Bargraph
100%
Bargraph ending value.
Function Select from the list if function is required or leave free if input is a protection only.
Offset Measured value offset.
Note: Some configuration items (e.g. Protection) stay without change when Property - Sensor is changed to
None.
Sensors availability
Sensors available on ID-DCU MARINE
AI1 - AI4
Resolution Sensor range HW jumper
Pt1000/°C, Ni1000/°C,
Pt1000/°F, Ni1000/°F
Fix, not configurable Resistance: 3-4
4-20 mA active,
±20 mA active (measures + only)
Adjustable -
see Hint
below.
For 20 mA input Current: 1-2
0-250 Ω, 0-2400
For 250 or 2400
Input
Resistance: 3-4
Tristate Resistance: 3-4
0 to 4 VDC Adjustable Voltage: 2-3
Sensors available on ID-DCU MARINE
AI5 - AI8
Resolution Sensor range HW jumper
Pt100/°C, Pt1000/°C, Ni100/°C, Ni1000/°C,
Pt100/°F, Pt1000/°F, Ni100/°F, Ni1000/°F
Fix, not configurable Resistance: 3-4
Thermocpl J/°C, Th K/°C, Th/°C,
Thermocpl J/°F, Th. K/°F, ThL/°F
Fix, not configurable Voltage: 2-3
4-20 mA active, ±20 mA active
Adjustable -
see Hint below.
For 20 mA input Current: 1-2
0-250 Ω, 0-2400
For 250 or 2400
input
Resistance: 3-4
±1 V, 0-100 mV For 1V or 100mV Voltage: 2-3
Tristate Resistance: 3-4
0 to 5 VDC Adjustable Voltage: 2-3
Configuration examples
Conversion from 4-20 mA to 6.0 Bar Oil pressure sensor (Wrn+Sd protection and Oil press function)

Table of Contents

Other manuals for ComAp InteliDrive DCU Marine

Related product manuals