EasyManua.ls Logo

ComAp InteliDrive DCU Marine - Stop Pulse; Comm AIN Fail; Comm bin Fail;Comm AOUT Fail;Comm BOUT Fail; DEF Lowlvlamp

ComAp InteliDrive DCU Marine
285 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
InteliDrive DCU Marine - 3.0.0 Global Guide
208
Related FW 3.0.0 Related applications All
Comm object 25
Description
1 sec pulse is generated in the beginning of Stop procedure.
Stop Pulse
6 back to List of LBO
Related FW 3.0.0 Related applications All
Comm object 269
Description
Communication warning fail when any Analog input module address does not communicate (2s timeout).
Comm AIN Fail
6 back to List of LBO
Related FW 3.0.0 Related applications All
Comm object 270
Description
Communication warning fail when any Binary input module address does not communicate (2s timeout).
Comm BIN Fail
6 back to List of LBO
Related FW 3.0.0 Related applications All
Comm object 271
Description
Communication warning fail when any Analog output module address does not communicate (2s timeout).
Comm AOUT Fail
6 back to List of LBO
Related FW 3.0.0 Related applications All
Comm object 272
Description
Communication warning fail when any Binary output module address does not communicate (2s timeout).
Comm BOUT Fail
6 back to List of LBO
Related FW 3.0.0 Related applications All
Comm object 1833
Description
Active signal indicates low level of Diesel Exhaust Fluid (DEF). It starts flashing when the DEF tank is
nearly empty (e.g. when the level is 10%), engine power may be reduced.
DEF LowLvlamp
6 back to List of LBO