EasyManuals Logo

ComAp InteliDrive DCU Marine User Manual

ComAp InteliDrive DCU Marine
285 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #141 background imageLoading...
Page #141 background image
InteliDrive DCU Marine - 3.0.0 Global Guide
141
Setpoint group Engine protect Related FW 3.0.0
Range [units] 0 .. Starting RPM [RPM]
Default value 30
Step 1
Comm object 8260 Related applications All
Config level Standard
Setpoint visibility Always
Description
Underspeed alarm is activated when engine is running and actual RPM is below the UnderSpeed threshold.
UnderSpeed
6 back to List of setpoints
Setpoint group Engine protect Related FW 3.0.0
Range [units] 0 .. Nominal RPM [RPM]
Default value 500
Step 1
Comm object 10139 Related applications All
Config level Standard
Setpoint visibility Always
Description
Binary output Ready to load is closed if RPM > MinLoadSpeed and engine is in Running state. Use this
output to enable/disable connecting of engine load. MinLoadSpeed is a condition to close BO Close Load
when panel I/0 button is used to connect load to engine.
MinLoadSpeed
6 back to List of setpoints
Setpoint group Engine protect Related FW 3.0.0
Range [units] Batt <V.. 40,0 [V]
Default value 30,0
Step 0,1
Comm object 9587 Related applications All
Config level Standard
Setpoint visibility Always
Description
Warning level for battery over voltage.
Batt > V
6 back to List of setpoints

Table of Contents

Other manuals for ComAp InteliDrive DCU Marine

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ComAp InteliDrive DCU Marine and is the answer not in the manual?

ComAp InteliDrive DCU Marine Specifications

General IconGeneral
BrandComAp
ModelInteliDrive DCU Marine
CategoryController
LanguageEnglish

Related product manuals