Checking the con rod
Commercial available tools:
Micrometer gauge
Internal measuring device
Con rod test device
Special tools:
Dial gauge. . . . . . . . . . . . . . . . . . 100400
W 02-09-03
z Remove piston and connecting rod.
W 02-09-03
© 40592-0
Checking small end bush
z Prepare internal measuring device:
Mount probe bolt for the appropriate measuring
range in the internal measuring device.
Mount dial gauge with approx. 1 mm pre-tension in
the internal measuring device.
Set micrometer gauge to 52 mm.
Balance the internal measuring device between
the test surfaces of the micrometer gauge and set
the meter at the reversal point of the pointer to "0".
© 34768-2