Cooling system
W 09-07-08
6
z Visually inspect the components.
© 40874-0
Installing coolant pump
z Insert new O-rings.
z Coat the O-rings with fitting compound.
O-rings:
75 x 3 mm (1)
80 x 3 mm (2)
1
2
© 36828_1
z Clean sealing surfaces.
Check drainage holes (arrows) for free
passage.
© 40876-0