7.2.7 Replacing a 2.5-inch HDD/SSD module
V CAUTION!
●
Only remove an HDD/SSD module during operation if the drive is not
currently being accessed. Observe the indicators for the
corresponding HDD/SSD modules, see section "Indicators on the
hot-plug HDD/SSD module" on page 369.
●
Under no circumstances should you remove an HDD/SSD module
while the system is in operation if you are not sure that the drive is
operated by a RAID controller and belongs to a disk array that is
operating in RAID level 1, 1E, 10, 5, 50, 6 or 60.
An HDD/SSD module can only be replaced during operation in
conjunction with a corresponding RAID configuration.
●
All HDD/SSD modules (drives) must be uniquely identified so that
they can be reinstalled in their original bays later. If this is not done,
existing data can be lost.
7.2.7.1 Preliminary steps
Ê "Locating the defective server" on page 45
Ê "Locating the defective component" on page 47
Only applicable for removing intact HDD/SSD modules:
Ê Before removing a non-defective HDD/SSD module, put the drive into
"Offline" mode using your RAID configuration software.
7.2.7.2 Removing the defective 2.5-inch HDD/SSD module
Ê Remove the HDD/SSD module as described in section "Removing 2.5-inch
HDD/SSD modules" on page 126.
Customer Replaceable Unit
(CRU)
Hardware: 5 minutes
Tools: tool-less