EasyManua.ls Logo

Fujitsu PRIMERGY RX2530 M1

Fujitsu PRIMERGY RX2530 M1
372 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
298 Upgrade and Maintenance Manual
RX2530 M1
System board and components
SATA DOM
With the Innodisk Serial ATA Disk on Module (SATADOM) an internal SSD
is offered. This SSD can be configured as a boot device or data storage
device.
iRMC microSD card
The iRMC microSD card is necessary for using the embedded Lifecycle
Management (eLCM) functionality of the iRMC.
15.2 CMOS battery
15.2.1 Replacing the CMOS battery
Safety notes
V CAUTION!
The CMOS battery must be replaced with an identical battery or with
a battery type recommended by the manufacturer.
Keep lithium batteries away from children.
Do not throw batteries into the trash can. Lithium batteries must be
disposed of in accordance with local regulations concerning special
waste.
For further safety information, please refer to section "Environmental
protection" in the operating manual of your server.
Ensure to insert the CMOS battery with the positive pole facing
up!
Upgrade and Repair Unit
(URU)
Hardware: 5 minutes
Tools: tool-less; recommended: tooth pick

Table of Contents

Other manuals for Fujitsu PRIMERGY RX2530 M1

Related product manuals