150 Upgrade and Maintenance Manual
RX2530 M1
Hard disk drives / solid state drives
7.3.4 Replacing a 3.5-inch HDD module
V CAUTION!
Only remove an HDD module during operation if the drive is not
currently being accessed. Observe the indicators on the HDD
module, see section "Indicators on the hot-plug HDD/SSD module"
on page 369.
Under no circumstances should you remove an HDD module while
the system is in operation if you are not sure that the drive is operated
by a RAID controller and belongs to a disk array that is operating in
RAID level 1, 1E, 10, 5, 50, 6 or 60.
An HDD module can only be replaced during operation in conjunction
with a corresponding RAID configuration.
All HDD modules (drives) must be uniquely identified so that they can
be reinstalled in their original bays later. If this is not done, existing
data can be lost.
7.3.4.1 Preliminary steps
Ê "Locating the defective server" on page 45
Ê "Locating the defective component" on page 47
Only applicable for removing intact HDD modules:
Ê Before removing a non-defective HDD module, put the drive into "Offline"
mode using your RAID configuration software.
I For further information, please refer to the "ServerView Suite RAID
Management" user guide.
Customer Replaceable Unit
(CRU)
Hardware: 5 minutes
Tools: tool-less

Table of Contents

Other manuals for Fujitsu PRIMERGY RX2530 M1

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu PRIMERGY RX2530 M1 and is the answer not in the manual?

Fujitsu PRIMERGY RX2530 M1 Specifications

General IconGeneral
BrandFujitsu
ModelPRIMERGY RX2530 M1
CategoryServer
LanguageEnglish

Related product manuals