RX2530 M1
Upgrade and Maintenance Manual 47
Basic hardware procedures
4.1.3 Locating the defective component
After determining the error class by the CSS or Global Error indicators (see
section "Determining the error class" on page 46) local diagnostic indicators on
the system board, HDD modules and power supply units (only slide-in units)
allow you to identify the defective component.
I For further information, refer to the "ServerView Suite Local Service
Concept (LSC)" manual.
4.1.3.1 Local diagnostic indicators on the system board
Using the Indicate CSS button
Ê Shut down and power off the server.
Ê Disconnect the AC power cord(s) from the system.
I It is mandatory to disconnect power cords in order to use the Indicate
CSS functionality.
Ê Press the Indicate CSS button to highlight defective components (see
section "Onboard indicators and controls" on page 360).
I In addition to local diagnostic indicators, CSS or Global Error LEDs
indicate, if the defective component is a customer replaceable unit or if a
service technician needs to be dispatched to replace the part (see
section "Determining the error class" on page 46).
If the system has been powered off to replace a non hot-plug unit, a
system of PRIMERGY diagnostics indicators guides you to the faulty
component.

Table of Contents

Other manuals for Fujitsu PRIMERGY RX2530 M1

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu PRIMERGY RX2530 M1 and is the answer not in the manual?

Fujitsu PRIMERGY RX2530 M1 Specifications

General IconGeneral
BrandFujitsu
ModelPRIMERGY RX2530 M1
CategoryServer
LanguageEnglish

Related product manuals