366 Upgrade and Maintenance Manual
RX2530 M1
Appendix
Status indicators
Pos. Indicator Status Description
3 ID indicator
blue on
server has been highlighted using
ServerView Operations Manager, iRMC
web frontend or the ID button on the front
panel for easy identification
blue flashing local monitor off
4
CSS
indicator
off no critical event (CSS component)
orange on prefailure detected (CSS component)
orange
flashing
CSS component failure
5
Global
Error
indicator
off no critical event (non CSS component)
orange on prefailure detected (non CSS component)
orange
flashing
indicates a failure of a non CSS
component.
Reasons for a failure may be:
over temperature measured by one of
the sensors
sensor is defective
CPU error
software detected an error
6
HDD/SSD
activity
indicator
green on data access in progress
7
Power-on
indicator
off
is off in the following case:
the system is in power-off mode but
connected to the mains (AC
connected)
green on
is on in the following cases:
the system has been switched on and
is in power-on delay
the system is powered on and in
normal operation (S0)
flashes slowly
(1/2 Hz)
iRMC S4 is not ready

Table of Contents