DIRECTION FC091194, REVISION 11 VIVID 7 SERVICE MANUAL
8 - 106 Section 8-20 - Verification - Functional Checks
8-6
"Lower Rear Cover
Replacements Procedure" on
page 8-10
4-2-2 "Power ON/ Boot UP" on page 4-3
4-2-3 "Power Shut Down" on page 4-7
3-6-5-1 "Connect a Probe" on page 3-21
4-3-5 "Performance Tests" on page 4-31
4-3-6 "2D Mode (B mode) Checks" on page 4-32
4-3-21-3 "Brakes and Direction Lock Checks" on page 4-80
8-7
"Software Loading Procedure -
Software Version v7.x, v6.x,
v5.x and v4.x" on page 8-12
4-4-1 "Software Configuration Checks" on page 4-82
Perform "Basic Functional Checks" on page 8-105
3-7-1-4 "Language Selection" on page 3-30
3-7-1-5 "Online Manual Language Selection" on page 3-31
8-8
"Software Loading Procedure -
Software Version v3.x" on page
8-38
4-4-1 "Software Configuration Checks" on page 4-82
Perform "Basic Functional Checks" on page 8-105
3-7-1-4 "Language Selection" on page 3-30
3-7-1-5 "Online Manual Language Selection" on page 3-31
8-9
"Software Loading Procedure -
Software Version v2.x" on page
8-54
4-4-1 "Software Configuration Checks" on page 4-82
Perform "Basic Functional Checks" on page 8-105
3-7-1-4 "Language Selection" on page 3-30
3-7-1-5 "Online Manual Language Selection" on page 3-31
8-11
"AC Power Replacement
Procedure" on page 8-82
10-7-4
10-7-5
10-7-6
10-7-7
10-7-8
10-7-9
Perform "Basic Functional Checks" on page 8-105
10-7-4 "Grounding Continuity" on page 10-14
10-7-5 "Chassis Leakage Current Test" on page 10-16
10-7-6 "Isolated Patient Lead (Source) Leakage–Lead to
Ground" on page 10-17
10-7-7 "Isolated Patient Lead (Source) Leakage–Lead to
Lead" on page 10-18
10-7-8 "Isolated Patient Lead (Sink) Leakage-Isolation Test"
on page 10-19
10-7-9 "Probe Leakage Current Test" on page 10-21
8-12
"DC Power Replacement
Procedure" on page 8-86
10-7-4
10-7-5
10-7-6
10-7-7
10-7-8
10-7-9
Perform "Basic Functional Checks" on page 8-105
10-7-4 "Grounding Continuity" on page 10-14
10-7-5 "Chassis Leakage Current Test" on page 10-16
10-7-6 "Isolated Patient Lead (Source) Leakage–Lead to
Ground" on page 10-17
10-7-7 "Isolated Patient Lead (Source) Leakage–Lead to
Lead" on page 10-18
10-7-8 "Isolated Patient Lead (Sink) Leakage-Isolation Test"
on page 10-19
10-7-9 "Probe Leakage Current Test" on page 10-21
8-13
"TX Power Replacement
Procedure" on page 8-89
10-7-4
10-7-5
10-7-6
10-7-7
10-7-8
10-7-9
Perform "Basic Functional Checks" on page 8-105
10-7-4 "Grounding Continuity" on page 10-14
10-7-5 "Chassis Leakage Current Test" on page 10-16
10-7-6 "Isolated Patient Lead (Source) Leakage–Lead to
Ground" on page 10-17
10-7-7 "Isolated Patient Lead (Source) Leakage–Lead to
Lead" on page 10-18
10-7-8 "Isolated Patient Lead (Sink) Leakage-Isolation Test"
on page 10-19
10-7-9 "Probe Leakage Current Test" on page 10-21
Table 8-22 Functional Test Matrix (cont’d) sheet 2 of 3
Section FRU Replacement Diagnostics
Leakage