EasyManuals Logo

Gemalto Cinterion EHS6 User Manual

Gemalto Cinterion EHS6
513 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #162 background imageLoading...
Page #162 background image
Cinterion
®
EHS6 AT Command Set
7.22 ATS7
EHS6_ATC_V03.001 15/12/3
Confidential / Released
Page 162 of 513
7.22 ATS7 Set number of seconds to wait for connection completion
ATS7 is implemented for compatibility reasons only, and has no effect.
Syntax
Parameter Description
000...060
(&F)
Notes
•Command ATS7 is dummy, and has no effect on module behavior.
Values greater than 60 (maximum 255) cause no error, but<n> will be restored to the maximum value of 60.
Read command will return value written by user or default value n=60.
Write command will return OK or ERROR. OK - when parameter <n> is in range, ERROR otherwise.
Despite OK returned in case of any parameter from range, no changes will be made.
Parameter is volatile.
Read Command
ATS7?
Response(s)
<n>
OK
Write Command
ATS7=<n>
Response(s)
OK
ERROR
PIN Last Reference(s)
- + - ITU-T V.250 [16]
<n>
(num)(&V)(&W)