11.12 AT+CGQMIN
EHS6_ATC_V03.001 15/12/3
Confidential / Released
Page 306 of 513
11.12 AT+CGQMIN Quality of Service Profile (Minimum acceptable)
This AT+CGQMIN command allows the TE to specify a minimum acceptable profile which is checked by the MT
against the negotiated profile returned in the Activate PDP Context Accept message.
The AT+CGQMIN write command specifies a profile for the context identified by the (local) context identification
parameter, <cid>.
A special form of the write command, AT+CGQMIN= <cid> causes the minimum acceptable profile for context
number <cid> to become undefined. In this case no check is made against the negotiated profile.
The AT+CGQMIN test command returns values supported as a compound value. If the MT supports several PDP
types, the parameter value ranges for each PDP type are returned on a separate line.
The AT+CGQMIN read command returns the current settings for each defined context. If no minimum profile was
explicitly specified for a context, simply OK will be returned, but default values will be used for that context.
Syntax
Parameter Description
Parameter specifies a particular PDP context definition (see AT+CGDCONT parameter <cid>). The parameter
is used in other PDP context-related commands.
Precedence class
[0] network subscribed value
Test Command
AT+CGQMIN=?
Response(s)
+CGQMIN: <PDP_type>, (list of supported <precedence>s), (list of supported <delay>s), (list of
supported <reliability>s), (list of supported <peak>s), (list of supported <mean>s)
OK
ERROR
+CME ERROR: <err>
Read Command
AT+CGQMIN?
Response(s)
[+CGQMIN: <cid>, <precedence>, <delay>, <reliability>, <peak>, <mean>]
[+CGQMIN: ...]
OK
ERROR
+CME ERROR: <err>
Write Command
AT+CGQMIN=[<cid>[, <precedence>[, <delay>[, <reliability>[, <peak>[, <mean>]]]]]]
Response(s)
OK
ERROR
+CME ERROR: <err>
PIN Last Reference(s)
+ + - 3GPP TS 27.007 [45]
<cid>
(num)(NV)
<precedence>
(num)(NV)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Gemalto Cinterion EHS6 and is the answer not in the manual?

Gemalto Cinterion EHS6 Specifications

General IconGeneral
BrandGemalto
ModelCinterion EHS6
CategoryControl Unit
LanguageEnglish

Related product manuals