Cinterion
®
EHS6 AT Command Set
20.5 AT^SSCNT
EHS6_ATC_V03.001 15/12/3
Confidential / Released
Page 479 of 513
20.5 AT^SSCNT Start and Stop Pulse Counter
The AT^SSCNT write command serves to read, start, restart and stop the pulse counter.
Syntax
Unsolicited Result Code
^SSCNT: <pulse>
The URC applies only to the Start-Stop mode set with AT^SCCNT, parameter <mode>=0. It is delivered once the
pulse counter result was requested with <action>=2 or the pulse counter was stopped with <action>=3. The
URC indicates the number of pulses counted.
Parameter Description
This parameter can only be used after configuring the pulse counter with AT^SCCNT by using <action>= 1 to
open pulse counter, otherwise the AT^SSCNT read and write command will return error. The <action> types
0, 1 and 2 apply only to the Start-Stop counter mode set with AT^SCCNT.
0 Reset and start pulse counter from 0.
1 Restart pulse counter and continue counting from the <pulse> value of the
last run.
2 Read out current <pulse> value.
Test Command
AT^SSCNT=?
Response(s)
^SSCNT:(list of supported <action>s)
OK
Read Command
AT^SSCNT?
Response(s)
^SSCNT: <action>
OK
If an error occurs:
ERROR
+CME ERROR: <err>
Write Command
AT^SSCNT=<action>
Response(s)
If <action>=0 or 1:
OK
If <action>=2 or 3:
OK
"^SSCNT" URC with parameter <pulse>
If an error occurs:
ERROR
+CME ERROR: <err>
PIN Last
- + -
<action>
(num)