8.2 AT+COPS Operator Selection
AT+COPS queries the present status of the EHS6's network registration and allows to determine whether auto-
matic or manual network selection shall be used.
Three operator selection modes are available:
Automatic
EHS6 searches for the home operator automatically. If successful the EHS6 registers to the home network.
If the home network is not found, EHS6 goes on searching. If a permitted operator is found, EHS6 registers
to this operator.
If no operator is found the EHS6 remains unregistered.
Manual
Desired operator can be determined using the AT+COPS write command. If the operator is found, EHS6 reg-
isters to it immediately. If the selected operator is forbidden, the EHS6 remains unregistered.
Manual/automatic
The ME first tries to find the operator determined via AT+COPS write command. If the ME fails to register to
this operator, then it starts to select another (permitted) operator automatically.
The AT+COPS test command consists of several parameter sets, each representing an operator present in the
network.
Each set contains the following information:
an integer indicating the availability of the operator,
long alphanumeric format of the operator's name,
short alphanumeric format of the operator's name,
numeric format representation of the operator.
an integer indicating the acccess technology of the operator.
The list of operators comes in the following order: Home network, networks referenced in SIM and other net-
works.
The AT+COPS read command returns the current <mode> and the currently selected operator. If no operator is
selected, <format> and <opName> are omitted.
The AT+COPS write command forces an attempt to select and register to the network operator. If the selected
operator is not available, no other operator will be selected (except <mode>=4). The selected operator name
<format> will apply to further read commands, too.
Command settings are effective over all serial interfaces of the EHS6.
Syntax
Test Command
AT+COPS=?
Response(s)
+COPS: [list of supported (<opStatus>, long alphanumeric <opName>, short alphanumeric <opName>,
numeric <opName>, <AcT>)s ]
OK
ERROR
+CME ERROR:<err>
Read Command
AT+COPS?
Response(s)
+COPS:<mode>[, <format>[, <opName>][, <AcT>]]
OK
ERROR
+CME ERROR:<err>

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Gemalto Cinterion EHS6 and is the answer not in the manual?

Gemalto Cinterion EHS6 Specifications

General IconGeneral
BrandGemalto
ModelCinterion EHS6
CategoryControl Unit
LanguageEnglish

Related product manuals