Cinterion
®
EHS6 AT Command Set
8.2 AT+COPS
EHS6_ATC_V03.001 15/12/3
Confidential / Released
Page 167 of 513
Parameter Description
Operator Status
0 Unknown operator
1 Operator available
2 Current operator (registered)
3 Operator forbidden
Operator Name
If test command: Operator name in long and short alphanumeric format and numeric format.
If read command: Operator name as per <format>.
If write command: Operator name in numeric format.
0 Automatic mode; <opName> field is ignored.
Default after SIM PIN authentication has completed and "+PBREADY" URC has
shown up. See also <mode>=2.
1 Manual operator selection
Write command requires <opName> in numeric format, i.e. <format> shall be
2.
Read command returns the current <mode> and the currently selected
<opName>. If no operator is selected, <format> and <opName> are omitted.
2
(P)
Manually deregister from network and remain unregistered until <mode>=0 or
1 or 4 is selected. Please keep in mind that the AT+COPS write command is SIM
PIN protected.
When SIM PIN is disabled or after SIM PIN authentication has completed and
"+PBREADY" URC has shown up the powerup default <mode>=2 automatically
changes to <mode>=0, causing the ME to select a network.
3 Set only <format> (for AT+COPS read command).
4 Automatic / manual selection; if manual selection fails, automatic mode
(<mode>=0) is entered (<opName> field will be present).
Parameter is global for all instances.
0
(&F)(D)
Long alphanumeric format of <opName>.
Write Command
AT+COPS=<mode>[, <format>[, <opName>][, <AcT>]]
Response(s)
OK
ERROR
+CME ERROR:<err>
PIN Last Reference(s)
± - - 3GPP TS 27.007 [45]
<opStatus>
(num)
<opName>
(str)(&V)
<mode>
(num)(&V)
<format>
(num)(&V)(&W)