EHS6 AT Command Set
2.8 AT+CFUN
EHS6_ATC_V03.001 15/12/3
Confidential / Released
Page 39 of 513
2.8 AT+CFUN Functionality Level
AT+CFUN controls EHS6's functionality level. It can also be used to reset the ME.
Syntax
Parameter Description
0 Switch off ME. ME returns OK followed by "^SHUTDOWN" URC.
See also AT^SMSO command.
1
(D)
Full functionality level.
4 Airplane mode.
Shut down TX and RX RF-circuits whereby EHS6 logs off from the network and
switches to AT+COPS=2. All AT commands whose execution requires a radio
connection will return an error response (such as "NO CARRIER" or "+CME
ERROR: NO NETWORK SERVICE". A list of AT commands supported during
Airplane mode can be found in Section 21.3, Availability of AT Com-
mands Depending on Operating Mode of ME.
After leaving Airplane mode by setting AT+CFUN=1 the AT+COPS write com-
mand shall be used to register to a network once again.
Test Command
AT+CFUN=?
Response(s)
+CFUN: (list of supported <fun>s), (list of supported <rst>s)
OK
ERROR
+CME ERROR: <err>
Read Command
AT+CFUN?
Response(s)
+CFUN: <power_mode>, <STK_mode>
OK
ERROR
+CME ERROR: <err>
Write Command
AT+CFUN=<fun>[, <rst>]
Response(s)
OK
ERROR
+CME ERROR: <err>
If <fun>= 0:
OK
^SHUTDOWN
If <rst>= 1:
OK
^SYSSTART
PIN Last Reference(s)
- + - 3GPP TS 27.007 [45]
<fun>
(num)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Gemalto Cinterion EHS6 and is the answer not in the manual?

Gemalto Cinterion EHS6 Specifications

General IconGeneral
BrandGemalto
ModelCinterion EHS6
CategoryControl Unit
LanguageEnglish

Related product manuals