Cinterion
®
EHS6 AT Command Set
15.2 AT+CPBR
EHS6_ATC_V03.001 15/12/3
Confidential / Released
Page 381 of 513
15.2 AT+CPBR Read from Phonebook
AT+CPBR serves to read one or more entries from the phonebook selected with AT command AT+CPBS.
The AT+CPBR test command returns the location range supported by the current phonebook storage, the maxi-
mum length of <number> field and the maximum length of <text> field.
Note: Length information may not be available while SIM storage is selected. If storage does not offer format
information, the format list contains empty parenthesizes.
The AT+CPBR write command determines the phonebook entry to be displayed with <location1> or a location
range from <location1> to <location2>. Hence, if no <location2> is given only the entry at
<location1> will be displayed.
If no entries are found at the selected location "OK" will be returned.
Syntax
Parameter Description
The first (lowest) location number within phonebook memory where to start reading. The maximum range sup-
ported by the current phonebook is given in the test command response.
If <location1> exceeds the upper bound <maxloc> (as indicated by the test command), command will
respond with "+CME ERROR: invalid index".
The last (highest) location number within phonebook memory where to stop reading. The maximum range sup-
ported by the current phonebook is given in the test command response.
If both <location1> and <location2> are in the range indicated by the test command parameter <max-
loc>, the list of entries will be output and terminated with "OK".
If <location2> exceeds the range indicated by the test command parameter <maxloc>, the list of entries will
be output but terminated with "+CME ERROR: invalid index".
Test Command
AT+CPBR=?
Response(s)
+CPBR: (1-<maxloc>), <nlength>, <tlength>
OK
ERROR
+CME ERROR: <err>
Write Command
AT+CPBR=<location1>[, <location2>]
Response(s)
[+CPBR: <location1>, <number>, <type>, <text>]
[+CPBR: <location2>, <number>, <type>, <text>]
OK
ERROR
+CME ERROR: <err>
PIN Last Reference(s)
+ + - 3GPP TS 27.007 [45],
3GPP TS 24.008 [40],
3GPP TS 11.11 [17], 3GPP TS
31.101 [18], 3GPP TS 31.102 [19]
<location1>
(num)
<location2>
(num)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Gemalto Cinterion EHS6 and is the answer not in the manual?

Gemalto Cinterion EHS6 Specifications

General IconGeneral
BrandGemalto
ModelCinterion EHS6
CategoryControl Unit
LanguageEnglish

Related product manuals