Cinterion
®
EHS6 AT Command Set
3.3 AT+CPAS
EHS6_ATC_V03.001 15/12/3
Confidential / Released
Page 101 of 513
3.3 AT+CPAS Activity Status
AT+CPAS execute command queries EHS6's activity status.
Syntax
Parameter Description
0 Ready (ME allows commands from TE)
1 Unavailable (ME does not allow commands from TE)
2 Unknown(ME is not guaranteed to respond to instructions)
3 Ringing (ME is ready for commands from TE, but the ringer is active)
4 Call in progress, held, waiting (ME is ready for commands from TE)
5 Asleep (ME is unable to process commands from TE because it is in a low
functionality state)
Test Command
AT+CPAS=?
Response(s)
+CPAS: (list of supported<pas>s)
OK
Exec Command
AT+CPAS
Response(s)
+CPAS: <pas>
OK
PIN Last Reference(s)
- + - 3GPP TS 27.007 [45]
<pas>
(num)