11.6 AT+CGDCONT
EHS6_ATC_V03.001 15/12/3
Confidential / Released
Page 292 of 513
11.6 AT+CGDCONT Define PDP Context
The AT+CGDCONT write command specifies the parameters for a PDP context identified by the context identifier
<cid>. The number of contexts that may be in a defined state at the same time is given by the range indicated
in the test command response. A special form of the write command (AT+CGDCONT=<cid>) causes the values
for context <cid> to become undefined.
The AT+CGDCONT read command returns the current settings for each defined PDP context.
The AT+CGDCONT test command returns supported values as a compound value.
Check of ACL (APN Control List):
The ACL will be checked only if a USIM is inserted. Before performing of context definition it will be checked if
the ACL-service is enabled and activated (3GPP TS 31.102 version 9.3.0 , sections 4.2.8 and 4.2.47). If yes all
APNs from ACL of EFACL of USIM will be read out and compared with the requested APN.
If the requested APN is listed in the ACL the context definition will be performed.
If the requested APN is empty ("") and ACL contains "network provided APN" the context definition will also
be requested.
If the APN is not listed in the ACL the command returns CME ERROR: 4 or CME ERROR: Operation not sup-
ported.
If the ACL-service is not enabled or not activated in the USIM or a GSM-SIM is inserted the context definition
will be performed without any checks.
Syntax
Test Command
AT+CGDCONT=?
Response(s)
+CGDCONT: (range of supported<cid>s), <PDP_type>, , , (list of supported <d_comp>s), (list of supported
<h_comp>s)
OK
ERROR
+CME ERROR: <err>
Read Command
AT+CGDCONT?
Response(s)
[+CGDCONT: <cid>, <PDP_type>, <APN>, <PDP_addr>, <d_comp>, <h_comp>]
[+CGDCONT: ...]
OK
ERROR
+CME ERROR: <err>
Write Command
AT+CGDCONT=[<cid>[, <PDP_type>[, <APN>[, <PDP_addr>]]]]
Response(s)
OK
ERROR
+CME ERROR: <err>
PIN Last Reference(s)
+ + - 3GPP TS 27.007 [45]

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Gemalto Cinterion EHS6 and is the answer not in the manual?

Gemalto Cinterion EHS6 Specifications

General IconGeneral
BrandGemalto
ModelCinterion EHS6
CategoryControl Unit
LanguageEnglish

Related product manuals