Cinterion
®
EHS6 AT Command Set
7.23 ATS8
EHS6_ATC_V03.001 15/12/3
Confidential / Released
Page 163 of 513
7.23 ATS8 Comma Dial Pause Time
ATS8 is implemented for compatibility reasons only, and has no effect.
Syntax
Parameter Description
000
(&F)
...255
Notes
•Command ATS8 is dummy, and has no effect on module behavior.
Read command will return value written by user or default value n=0.
Write command will return OK or ERROR. OK - when parameter <n> is in range, ERROR otherwise.
Despite OK returned in case of any parameter from range, no changes will be made.
Parameter is volatile.
Read Command
ATS8?
Response(s)
<n>
OK
Write Command
ATS8=<n>
Response(s)
OK
PIN Last Reference(s)
- + - ITU-T V.250 [16]
<n>
(num)(&V)(&W)