15. Phonebook Commands
EHS6_ATC_V03.001 15/12/3
Confidential / Released
Page 380 of 513
15. Phonebook Commands
The AT commands described in this chapter allow the external application to access the phonebooks located in
the EHS6's memory or on the attached Subscriber Identity Module (SIM).
15.1 AT+CNUM Read own numbers
AT+CNUM returns the subscribers own number(s) from the SIM.
Syntax
Parameter Description
Optional alphanumeric string associated with <number>.
Phone number in format specified by <type>.
Type of address octet, see also: AT+CPBR <type>.
Test Command
AT+CNUM=?
Response(s)
OK
Exec Command
AT+CNUM
Response(s)
[+CNUM: [<alpha>], <number>, <type>]
[+CNUM: ... ]
OK
ERROR
+CME ERROR: <err>
PIN Last Reference(s)
+ + - 3GPP TS 27.007 [45]
<alpha>
(str)
<number>
(str)
<type>
(str)