Table 69: Chassis Component Alarm Conditions on EX9200
Switches (continued)
Remedy
Alarm
SeverityAlarm Condition
Chassis
Component
Install a host subsystem in the empty
slot.
Minor
(yellow)
A host subsystem has
been removed.
Host
subsystem
Replace the failed host subsystem.Major
(red)
A host subsystem has
failed.
Replace the failed components.Major
(red)
Too many hot-swap
interrupts are occurring.
This message generally
indicates that a hardware
component that plugs
into the router’s
backplane from the front
(generally, an FPC) is
broken.
Hot
swapping
Install a power supply in the empty
slot.
Minor
(yellow)
A power supply has been
removed from the chassis.
Power
supplies
Replace the failed power supply or
power entry module.
Major
(red)
A power supply has a high
temperature.
Check power supply input
connection.
Major
(red)
A power supply input has
failed.
Check power supply output
connection.
Major
(red)
A power supply output
has failed.
Replace the failed power supply.Major
(red)
A power supply has failed.
When two AC power supplies are
installed, install one power supply in
an odd-numbered slot and the other
power supply in an even-numbered
slot.
Major
(red)
Invalid AC power supply
configuration.
When two DC power supplies are
installed, install one power supply in
an odd-numbered slot and the other
power supply in an even-numbered
slot.
Major
(red)
Invalid DC power supply
configuration.
Do not mix AC and DC power
supplies.
Major
(red)
ACand DC power supplies
are installed.
Install an additional power supply.Major
(red)
Inadequate number of
power supplies.
Copyright © 2017, Juniper Networks, Inc.304
EX9208 Switch Hardware Guide