Function library
7-27
L
EDSVS9332P-D21 EN 3.0
Signal NoteSource
Designation ListCFGDIS formatDISType
POS-RESETED d - - - - Position status display
HIGH = Position program in status “Prg-Reset”
(see “program control” E 7-71)
POS-RUNNING d - - - - Position status display
POS-R UNNING = HIGH: Program run is started and is not interrupted by controller
inhibit, faults or manual control.
POS-RUNNING = LOW and POS-STARTED = HIGH: Program run interrupted; for
continuing the program run a new edge to POS-PRG-START is r equired.
POS-S-RAMPS d C1361/17 bin C1361/17 2 HIGH level = S profile is active (see S-shaped ramps” E 7-61)
POS-SETPOS ph C1220/2
C1221/2
dec [units]
dec [inc]
- - Current position setpoint; for scaling see formula 1
POS-START-PS a C1363/1 dec [inc] C1362/1 1 Start program set
Number of the program set with which the program run is to be started. In the
standard configurations (see C0005) it is connected with C1211,
POS-STARTED d - - - - Position status display
HIGH = Program started
If the program has been interrupted by c o ntroller inhibit, fault or manual homing,
POS-STARTED remains HIGH. The program can only c ontinue if a new signal is
applied to POS-PRG-START.
(see “program control” E 7-71)
POS-STDBY-ACT d - - - - HIGH = stand-by operation is active (see “Stand-by operation” E 7-81)
POS-STDBY-STP d C1361/16 bin C1360/16 2 HIGH = terminates the stand-by operation, if ”STDBY” is selected in the POS mode
(C1311 = 30). No other function. (see “Stand-by operation” E 7-81)
POS-STOPPED d - - - - Position status display
HIGH = Program and dri ve have been stopped or drive is being stopped
(see “program control” E 7-71)
POS-TARGET ph C1220/1
C1221/1
dec [units]
dec [inc]
- - current target position in real measuring system; for scaling see formula 1
POS-V-OVERRID a C1363/2 dec [%] C1362/2 1 Reduces the traversing and final speed as well as the manual traversing speed
and the homing speed.
Note: Only positive override values are effective, negative values will be evaluated
as zero. (See ”Override” E 7-63)
POS-VFIN-REAC d - - - - HIGH = current final speed reached
POS-VFINAL ph C1245/3 dec [inc] - - Acceleration, absolute value for c urrent PS, for scaling see formula 3.
POS-VSET ph C1245/1 dec [inc] - - Current speed setpoint; for scaling see formula 2
POS-VTRAV ph C1245/2 dec [inc] - - Final speed, absolute value for c urrent PS, for scaling see formula 2.
POS-VTRAV-REA d - - - HIGH = current traversing speed reached
POS-WAITSTATE d C1360/22 bin C1361/22 2002 Completion of positioning in the actual program block is delayed to wait until the
possibly occurring following error has been eliminated when reaching the target.
HIGH = POS-IN-TARGET is not set, the actual positioning is not completed.
(see chapter “Target window” E 7-65)