Function library
7-117
L
EDSVS9332P-D21 EN 3.0
BCD2
C1710/2
C1713
C1714
CTRL
+
+
C1715
S&H
C1719/6
BCD2-LOAD
C1718/6
C1710/1
Code/Subcode
(Cxxxx/yyy)
C1717
C1716
BCD2-BUSY
BCD2
1
C1719/7
BCD2-BUSY-IN
C1718/7
1
C1719/8
BCD2-FAIL-IN
C1718/8
BCD2-FAIL
C1719/2
BCD2-DATA1
C1718/2
C1719/3
BCD2-DATA2
C1718/3
C1719/4
BCD2-DATA3
C1718/4
C1719/5
BCD2-DATA4
C1718/5
C1719/1
BCD2-READ
C1718/1
BCD2-SIGN
BCD2-SEL1
BCD2-SEL2
BCD2-SEL3
BCD2-SEL4
BCD2-SEL5
BCD2-SEL6
BCD2-SEL7
BCD2-SEL8
BCD2-NEW-DATA
BCD2-EOT
BCD2-DATA-FLT
C1712
C1711
BCD-
LOGIC
2
0
2
1
2
2
2
3
Fig. 7-80 Function block BCD2
Signal
Source Note
Name Type DIS DIS format CFG List
BCD2-DATA1 d C1719/2 bin C1718/2 2 Data input (LSB)
BCD2-DATA2 d C1719/3 bin C1718/3 2 Data input
BCD2-DATA3 d C1719/4 bin C1718/4 2 Data input
BCD2-DATA4 d C1719/5 bin C1718/5 2 Data input (MSB)
BCD2-READ d C1719/1 bin C1718/1 2 Only required for handshake mode:
•
Signal must be applied at the controll e r for at least
2ms.
•
LOW-HIGH edge starts the data transmission for a
BCD.
BCD2-LOAD d C1719/6 bin C1718/6 2 LOW-HIGH edge = Write data to the code.
BCD2-BUSY-IN d C1719/7 bin C1718/7 2 Generating a collective busy signal
BCD2-FAIL-IN d C1719/8 bin C1718/8 2 Generating a collective fail signal
BCD2-SIGN d - - - - HIGH = Read sign.
BCD2-SEL1 d - - - - HIGH = Read 1st BCD.
BCD2-SEL2 d - - - - HIGH = Read 2nd BCD.
BCD2-SEL3 d - - - - HIGH = Read 3rd BCD.
BCD2-SEL4 d - - - - HIGH = Read 4th BCD.
BCD2-SEL5 d - - - - HIGH = Read 5th BCD.
BCD2-SEL6 d - - - - HIGH = Read 6th BCD.
BCD2-SEL7 d - - - - HIGH = Read 7th BCD.
BCD2-SEL8 d - - - - HIGH = Read 8th BCD.
BCD2-NEW-DATA d - - - - HIGH = BCD accepted, transmit next BCD.
BCD2-EOT d - - - - HIGH = all BCDs read or ”CANCEL” recognised.
BCD2-DATA-FLT d - - - - HIGH = BCD code (see chapter 7.5.28.1).
BCD2-BUSY d - - - - HIGH = Data are being transmitted to code.
BCD2-FAIL d - - - - HIGH = Data transmission to code is faul ty.