Function library
7-118
L
EDSVS9332P-D21 EN 3.0
BCD3
C1720/2
C1723
C1724
CTRL
+
+
C1725
S&H
C1729/6
BCD3-LOAD
C1728/6
C1720/1
Code/Subcode
(Cxxxx/yyy)
C1727
C1726
BCD3-BUSY
BCD3
1
C1729/7
BCD3-BUSY-IN
C1728/7
1
C1729/8
BCD3-FAIL-IN
C1728/8
BCD3-FAIL
C1729/2
BCD3-DATA1
C1728/2
C1729/3
BCD3-DATA2
C1728/3
C1729/4
BCD3-DATA3
C1728/4
C1729/5
BCD3-DATA4
C1728/5
C1729/1
BCD3-READ
C1728/1
BCD3-SIGN
BCD3-SEL1
BCD3-SEL2
BCD3-SEL3
BCD3-SEL4
BCD3-SEL5
BCD3-SEL6
BCD3-SEL7
BCD3-SEL8
BCD3-NEW-DATA
BCD3-EOT
BCD3-DATA-FLT
C1722
C1721
BCD-
LOGIC
2
0
2
1
2
2
2
3
Fig. 7-81 Function block BCD3
Signal
Source Note
Name Type DIS DIS format CFG List
BCD3-DATA1 d C1729/2 bin C1728/2 2 Data input (LSB)
BCD3-DATA2 d C1729/3 bin C1728/3 2 Data input
BCD3-DATA3 d C1729/4 bin C1728/4 2 Data input
BCD4-DATA4 d C1729/5 bin C1728/5 2 Data input (MSB)
BCD3-READ d C1729/1 bin C1728/1 2 Only required for handshake mode:
•
Signal must be applied at the controll e r for at least
2ms.
•
LOW-HIGH edge starts the data transmission for a
BCD.
BCD3-LOAD d C1729/6 bin C1728/6 2 LOW-HIGH edge = Write data to the code.
BCD3-BUSY-IN d C1729/7 bin C1728/7 2 Generating a collective busy signal
BCD3-FAIL-IN d C1729/8 bin C1728/8 2 Generating a collective fail signal
BCD3-SIGN d - - - - HIGH = Read sign.
BCD3-SEL1 d - - - - HIGH = Read 1st BCD.
BCD3-SEL2 d - - - - HIGH = Read 2nd BCD.
BCD3-SEL3 d - - - - HIGH = Read 3rd BCD.
BCD3-SEL4 d - - - - HIGH = Read 4th BCD.
BCD3-SEL5 d - - - - HIGH = Read 5th BCD.
BCD3-SEL6 d - - - - HIGH = Read 6th BCD.
BCD3-SEL7 d - - - - HIGH = Read 7th BCD.
BCD3-SEL8 d - - - - HIGH = Read 8th BCD.
BCD3-NEW-DATA d - - - - HIGH = BCD accepted, transmit next BCD.
BCD3-EOT d - - - - HIGH = all BCDs read or ”CANCEL” recognised.
BCD3-DATA-FLT d - - - - HIGH = BCD code (see chapter 7.5.28.1).
BCD3-BUSY d - - - - HIGH = Data are being transmitted to code.
BCD3-FAIL d - - - - HIGH = Data transmission to code is faul ty.