Technical data
3-5
L
EDSVS9332P-B EN 3.0
3.3.3 Types 9326 to 9332
Type EVS9326-EP EVS9327-EP EVS9328-EP EVS9329-EP EVS9330-EP EVS9331-EP EVS9332-EP
Order No. EVS9326-EP EVS9327-EP EVS9328-EP EVS9329-EP EVS9330-EP EVS9331-EP EVS9332-EP
Type EVS9326-CP EVS9327-CP EVS9328-CP
Order No. EVS9326-CP EVS9327-CP EVS9328-CP
Mains voltage V
r
[V] 320 V - 0 % V
r
528V+0%;45Hz-0%...65Hz+0%
Alternative DC supply V
DC
[V] 460 V - 0 % V
DC
740 V + 0 %
Mains current with mains filter
Mains current without mains filter
I
r
[A] 20.5
-
27.0
43.5
44.0
-
53.0
-
78.0
-
100
-
135
-
Rated data for operation at a mains : 3 AC / 400V / 50Hz/60Hz
Motor power (4-pole ASM)
P
r
[kW] 11.0 15.0 22.0 30.0 45.0 55.0 75.0
p
(
p
)
P
r
[hp] 15.0 20.5 30.0 40.0 60.0 73.5 100.0
Output power UVW (8 kHz*) S
r8
[kVA] 16.3 22.2 32.6 40.9 61.6 76.2 100.5
Output power +U
DC
,-U
DC
2)
P
DC
[kW] 0 10 4 0 5 0 0
Output current (8 kHz*)
1)
I
r8
[A] 23.5 32.0 47.0 59.0 89.0 110.0 145.0
Output current (16 kHz*)
1)
I
r16
[A] 15.3 20.8 30.6 38.0 58.0 70.0 90.0
Max. output current (8 kHz*) I
max8
[A] 35.3 48.0 70.5 88.5 133.5 165.0 217.5
Max. output current (16 kHz*) I
max16
[A] 23.0 31.2 45.9 57.0 87.0 105.0 135.0
Max. standstill current (8 kHz*) I
08
[A] 23.5 32.0 47.0 52.0 80.0 110.0 126.0
Max. standstill current (16 kHz*) I
016
[A] 15.3 20.8 30.6 33.0 45.0 70.0 72.0
Rated data for operation at a mains : 3 AC / 480V / 50Hz/60Hz
Motor power (4-pole ASM)
P
r
[kW] 11.0 18.5 30.0 37.0 45.0 55.0 90.0
p
(
p
)
P
r
[hp] 15.0 25.0 40.0 49.5 60.0 73.5 120.0
Output power UVW (8 kHz*) S
r8
[kVA] 18.5 25.0 37.0 46.6 69.8 87.3 104.0
Output power +U
DC
,-U
DC
2)
P
DC
[kW] 0 12 4.8 0 6 0 6
Output current (8 kHz*) I
r8
[A] 22.3 30.4 44.7 56.0 84.0 105.0 125.0
Output current (16 kHz*) I
r16
[A] 14.5 19.2 28.2 35.0 55.0 65.0 80.0
Max. output current (8 kHz*)
1)
I
max8
[A] 33.5 45.6 67.1 84.0 126.0 157.5 187.5
Max. output current (16 kHz*)
1)
I
max16
[A] 21.8 28.8 42.3 52.5 82.5 97.5 120.0
Max. standstill current (8 kHz*) I
08
[A] 22.3 30.4 44.7 49.0 72.0 105.0 111.0
Max. standstill current (16 kHz*) I
016
[A] 14.5 19.2 28.2 25.0 36.0 58.0 58.0
Motor voltage a
M
[V] 0-3× V
Mains
Power loss P
loss
[W] 360 430 640 810 1100 1470 1960
Power derating [%/K]
[%/K]
[%/m]
9326: at 40 °C < T
amb
< 55 °C: 2%/K (not UL approved)
9327 - 9332: at 40 °C < T
amb
< 50 °C: 2.5%/K (not UL approved)
1000 m amsl < h 4000 m amsl: 5%/1000m
Weight m[kg] 7.5 12.5 12.5 12.5 36.5 59 59
1)
The currents apply to a periodical load cycle with 1 minute overcurrent with the current mentioned
here and 2 minutes base load with 75% I
ratedx
2)
When operated under rated load, the controller can supply this power additionally.
*
Switching frequency of the inverter (C0018)
Show/Hide Bookmarks