Configuration
7-324
L
EDSVS9332P-D22 EN 3.0
Code ImportantPossible settings
No. SelectionLenzeLCD
[C0005] SIGNAL CFG 1000
Signal configuration
(Predefined basic configurations)
The first digi t indicates the predefined basic
function
1xxx: Speed control
2xxx: Absolute positioning via home position
The second digit indicates additional functions
x0xx: No additional function
x2xx: With position switch points and Teach
function
x6xx: ???
The third digit i ndicates the predefined voltage
source for the control terminals
xx0x: External supply voltage
xx1x: Internal supply voltage
The fourth digit indicates the predefined devic e
control
xxx0: Terminal control
xxx3: AIF
0 COMMON Modified basic configuration
100 Empty All internal connections are deleted
1000 Speed mode Speed control
20000
20003
20010
20013
20200
20203
20210
20213
Standard pos
abs AIF
abs/supply
abs/supply AIF
relative
relative AIF
relative/supply
relative/supply AIF
Absolute positioning via home position
22000
22003
22010
22013
22200
22203
22210
22213
abs/sp
abs/sp AIF
abs/sp/supply
abs/sp/supply AIF
relative/sp
relative/sp AIF
relative/sp/supply
relative/sp/supply AIF
Absolute positioning with home positions and
Teach function
26000
26010
set pos.sel
set pos. sel/supply
External path c ontrol in preparation for a
multi-axis positioning
[C0006] OP MODE
Æ
2
3
22
Servo control asynchronous motors in star
connection
Servo control synchronous motors in star
connection
Servo control asynchronous motors in delta
connection
Motor control mode
Æ
depending on C0086
Change of C0086 resets value to the assigned
default setting
Change of C0006 sets C0086 = 0!
C0009 LECOM ADDRESS 1 1 {1} 99 LECOM device ad dress
Bus device number when operated via interface
10, 20, ..., 90 reserved for broadcast to device
groups for RS232, RS485, fibre optics.
C0011 NMAX 3000 500 {1 rpm} 16000 Max. speed Nmax
Reference value for the absolute and relative
setpoint selection for the acceleration and
deceleration times.
For parameter setting via interface:
Major changes in one step should only be made
when the controller i s inhibited.
C0012 TIR (ACC) 0,000 0.000 {0.001 s} 999.900 NSET acceleration time T
ir
for the main setpoint of NS ET (referring to
speed varia tion 0 ... n
max
)