Configuration
7-325
L
EDSVS9332P-D22 EN 3.0
Code ImportantPossible settings
No. SelectionLenzeLCD
C0013 TIF (DEC) 0.000 0.000 {0.001 s} 999.900 NSET deceleration time Tif
for the main setpoint of NS ET (referring to
speed varia tion n
max ...
0)
C0017 FCODE (QMIN) 50 -16000 {1 rpm} 16000 FCODE (Qmin)
Switching threshold n
act
<n
x
n
act
< C0017 activates the comparator output
CMP1-OUT
C0018 1
Switching frequency switch
0 16/8 kHz sine Optimum noise reduction with automatic
changeover to 8 kHz
1 8kHzsine Performance-optimised operation
2 16 kHz sine Noise-optimised opera tion
C0019 THRESH NACT = 0 0 0 {1 rpm} 16000 Threshold n
act
=0
Threshold detection at n
act
=0
C0021 SLIPCOMP 0.00 0.00 {0.01 %} 20.00 Slip compensation
active only in sensorless control below the value
of C0291
C0022 IMAX CURRENT
Æ
0 {0.01 A} 1.50 I
N
I
max
limit current
Æ
depending on C0086
Change of C0086 resets value to the assigned
default setting (1.5 × I motor)
[C0025] FEEDBA CK TYPE 10
Feedback
Input of the encoder specified on the nameplate
of the Lenze motor:
C0025 automatically changes C0420, C0490,
C0495
0 COMMON C0420, C0490 or C0495 was changed
subsequently
10 RSx (Resolver) The resolver is designated with RSxxxxxxxx.
110
111
112
113
IT-512-5V
IT-1024-5V
IT-2048-5V
IT-4096-5V
Incremental encoder with TTL level
210
211
212
213
IS-512-5V
IS-2024-5V
IS-2048-5V
IS-4096-5V
Sin/cos encoder
310 AS-512-8V Single-turn sin/cos encoder with RS485
interface by Stegmann company (the voltage
must be entered manually)
410 AM-512-8V Multi-turn sin/c os encoder by Stegmann
company (the voltage must be entered
manually)
C0026
-199.99 {0.01 %} 199.99
FCODE (OffsetAIN)
Freely assignable code for relative analog
signals
1 FCODE (OFFSET) 0.00 Offset for terminal X6/1,2
2 FCODE (OFFSET) 0.00 Offset for terminal X6/3,4
C0027
-199.99 {0.01 %} 199.99
FCODE (AIN)
Freely assignable code for relative analog
signals
1 FCODE (GAIN) 100.00 Gain X6/1,2
2 FCODE (GAIN) 100.00 Gain X6/3,4
C0030 DFOUT CONST 3 0
1
2
3
4
5
6
256 inc/rev
512 inc/rev
1024 inc/rev
2048 inc/rev
4096 inc/rev
8192 inc/rev
16384 inc/rev
DFOUT constant
Constant for the digital frequency output in
increments per revolution
Show/Hide Bookmarks