Configuration
7-334
L
EDSVS9332P-D22 EN 3.0
Code ImportantPossible settings
No. SelectionLenzeLCD
[C0339] Selection list 1
ARIT1
1 ARIT1-IN1 1000 FIXED0%
Input signal configuration
2 ARIT1-IN2 1000 FIXED0%
C0340
0
1 (C0339/1)
2 (C0339/2)
[C0350] CAN ADDRESS 1 1 {1} 63 CAN
Node address
[C0351] CAN BAUDRATE 0 0
1
2
3
4
500 kbits/s
250 kbits/s
125 kbits/s
50 kbits/s
1000 kbits/s
CAN
Baud rate
[C0352] CAN MST 0 0
1
Slave
Master
CAN
Establishing a master o peration
C0353 0
1
C0350
C0354
CAN
Source for IN/OUT addresses
1 CAN ADDR SEL1 0
0
CAN-IN1/OUT1 address
2 CAN ADDR SEL2 0 CAN-IN2/OUT2 address
3 CAN ADDR SEL3 0 CAN-IN3/OUT3 address
C0354 1 {1} 512
CAN
1 IN1 ADDR2 1
CAN-Bus IN/OUT node addresses 2
2 OUT2 ADDR2 129
3 IN2 ADDR2 257
4 OUT2 ADDR2 258
5 IN3 ADDR2 385
6 OUT2 ADDR2 386
C0355
0
0 {1} 2047
CAN
1 IN1 ID
CAN-bus identifier
2 OUT1 ID
3 IN2 ID
4 OUT2 ID
5 IN3 ID
6 OUT3 ID
C0356 0 {1 ms} 65000 CAN
Time settings
1 CAN BOOT UP 3000 CAN boot up
2 OUT2 CYCLE 0 CAN-OUT2 cycle
3 OUT3 CYCLE 0 CAN-OUT3 cycle
4 CAN DELAY 20 CAN OUT 2/3 delay time
[C0357] 0 {1 ms} 65000 CAN
CAN-Bus monitoring time for I
Nx
1 CE1MONIT TIME 3000 CE1 monitoring time
2 CE2MONIT TIME 3000 CE2 monitoring time
3 CE3MONIT TIME 3000 CE3 monitoring time
C0358 RESET NODE 0 0
1
No function
CAN reset
CAN
Install CAN bus reset node
C0359 CAN S TATE
0
0
1
2
3
Operational
Pre-Operational
Warning
Bus off
CAN
Status di splay