Configuration
7-333
L
EDSVS9332P-D22 EN 3.0
Code ImportantPossible settings
No. SelectionLenzeLCD
C0262 MPOT1 TIR 10.0 0.1 {0.1 s} 6000.0 MPOT1
Acceleration time
(referring to change 0 ... 100 %)
C0263 MPOT1 TIF 10.0 0.1 {0.1 s} 6000.0 MPOT1
Deceleration time
(referring to change 0 ... 100 %)
C0264 MPOT1 ON/OFF 0 0
1
2
3
4
5
No change
Deceleration with T
if
to 0%
Deceleration with T
if
to C0261
Jump with T
if
=0to0%
Jump with T
if
= 0 to C0261
Acceleration with T
ir
to C0260
MPOT1
Deactivation function of motor pot
Function which is executed when motor pot is
deactivated via the input MPOT1-INACTIVE.
C0265 MPOT1 INIT 0 0
1
2
Value during mains failure
lower limit of C0261
0%
MPOT1
Initialisation.Value which is accepted during
mains switching and activated motor
potentiometer.
[C0267] → Selection list 2 Digital inputs o f motor potentiometers
1 UP 1000 FIXED0 Mpot-UP
2 DOWN 1000 FIXED0 MPOT-Down
[C0268] MPOT1-INACT 1000 FIXED0 → Selection list 2 MPOT1
Input signal configuration
C0269
0
1 (C0267/1)
2 (C0267/2)
3 (C0268)
C0325 VP2 ADAPT 1.0 0.1 {0.1} 500.0 PCTRL
Process controller adaptation gain (V
p2
)
C0326 VP3 ADAPT 1.0 0.1 {0.1} 500.0 PCTRL
Process controller adaptation gain (V
p3
)
C0327 SET2 ADAPT 100.00 0.00 {0.01 %} 100.00 PCTRL
Set speed threshold nset2 of the process
controller adaptation
(condition: C0327 > C0328)
C0328 SET1 ADAPT 0.00 0.00 {0.01 %} 100.00 PCTRL
Set speed threshold nset1 of the process
controller adaptation
(condition: C0328 < C0327)
C0329 ADAPT ON/OFF 0 0
1
2
3
No process controller adaptation
External via input
Adaptation via setpoint
Adaptation via control difference
PCTRL
Activate process controller adaptation
C0332 PCTRL TIR 0.000 0.000 {0.001 s} 999.900 PCTRL
Acceleration time Tir
Refers to setpoint change 0...100 %
C0333 PCTRL TIF 0.000 0.000 {0.001 s} 999.900 PCTRL
Deceleration time Tif
Refers to setpoint change 0...100 %
C0336 ACT VP
0
0.0 {0.1} 500.0 PCTRL
Current Vp
C0337 BI/UNIPOLAR 0 0
1
Bipolar
Unipolar
PCTRL
Bipolar/unipolar range of ac tion
C0338 ARIT1 FUNCT 1 0
1
2
3
4
5
OUT = IN1
IN1 + IN2
IN1 - IN2
IN1 * IN2
IN1 / IN2
IN1/(100% - IN2)
ARIT1
Function selection