EasyManua.ls Logo

Lenze 9300 - Page 463

Lenze 9300
591 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Configuration
7-332
L
EDSVS9332P-D22 EN 3.0
Code ImportantPossible settings
No. SelectionLenzeLCD
C0200 S/W ID
0
Software identification
Software identification
C0201 S/W DATE
0
Date of software release
Creation da te
C0202 I NTERNAL IO
0
0.000 {0.001} 100.000 Internal identification
C0203 COMM. NO.
0
x / xxxx / xxxxx Commission number
C0204 SERIAL-NO.
0
0 {1} 65535 Serial number
C0206 PRODUCT DATE
0
Date of production
C0207 DL INFO 1
0
Download info 1
C0208 DL INFO 2
0
Download info 2
C0209 DL INFO 3
0
Download info 3
C0220 NSET TIR ADD 0.000 0.000 {0.001 s} 999.900 NSET
Additional setpoint Tir
Acceleration time T
ir
of the additional setpoint
for NSET
(referring to speed variation of 0 ... n
max.
)
C0221 NSET TIF ADD 0.000 0.000 {0.001 s} 999.900 NSET
Additional setpoint Tif
Deceleration time T
if
of the additional setpoint
for NSET
(referring to speed variation of 0 ... n
max.
)
C0222 PCTRL VP 1.0 0.1 {0.1} 500.0 PCTRL
Vp gain
C0223 PCTRL TN 400 20 {1 ms} 99998 PCTRL
Tn integral component
99999 ms: Switched off
C0224 PCTRL KD 0.0 0.0 {0.1} 5.0 PCTRL
Kd differential component
C0241 NSET RFG-I = O 1.00 0.00 {0.01 %} 100.00 NSET
Threshold ramp function generator for main
setpoint
Input = output , (100 % = n
max
)
C0244 BRK M SET 0.00 -100.00 {0.01 %} 100.00 BRK1
Holding torque of the DC injection brake
100 % = value of C0057
C0250 FCODE 1BIT 0 0
1
lower limit
upper limit
FCODE 1bit digital
C0252 ANGLE OFFSET 0 -245760000 {1 inc} 245760000 DFSET
Phase offset
Fixed phase offset for digital frequency
configuration
1 rev. = 65536 inc
C0253 ANGLE N-TRIM -32767 {1 inc} 32767 DFSET
Speed-dependent phase trimming
Æ
depending on C0005, C0025, C0490
Change of C0005, C0025, or C0490 resets
C0253 to the default setting
1 rev. = 65536 inc
C0253 is reached at 15000 rpm
C0254 VP ANGLE CTRL 0.4000 0.0000 {0.0001} 3.9999 MCTRL
Vp phase controller
C0255 THRESHOLD P03 327680 10 {1 inc} 1800000000 Following error limit P03
1 rev. = 65536 inc
Following error > C0255 releases fault ”P03”
C0260 MPOT1 HIGH 100.00 -199.99 {0.01 %} 199.99 MPOT1
Upper limit (condition: C0260 > C0261)
C0261 MPOT1 LOW -100.00 -199.99 {0.01 %} 199.99 MPOT1
Lower limit (condition: C0261 < C0260)
Show/Hide Bookmarks

Table of Contents

Other manuals for Lenze 9300

Related product manuals