Configuration
7-363
L
EDSVS9332P-D22 EN 3.0
Code ImportantPossible settings
No. SelectionLenzeLCD
C1280 POS. CONTROL 0
0 {1} 65535
Control word positioning
Bit 0
Bit 1
Bit 2
Bit 3
Bit 4
Bit 5
Bit 6
Bit 7
Bit 8 ... 15
Program start
Program stop
Program reset
Program abort
Manual opera tion
Negative manual positioning
Positive manual positioning
Manual homing
reserved
C1283 POS. STATUS
0
0
5
10
11
12
15
20
25
26
30
35
36
50
51
55
56
57
58
59
62
63
80
85
program mode
rdy to start
started
started-dig
started-rem
started-break
program end
stopped-dig
stopped-rem
STDBY mode
reset-dig
reset-rem
manual-dig
manual-rem
manu-neg-dig
manu-neg-rem
manu-pos-dig
manu-pos-rem
neg+pos active
manu-ref-dig
manu-ref-rem
POS-LOOP-INH
POS-PSET-SWT
Positioning state
The state is only updated under the following
conditions:
•
The power stage is supplied
(DCTRL-RDY=1),
•
No fault
(DCTRL-TRIP=0, DCTRL-FAIL-QSP=0),
•
The drive i s enabled (DCTRL-CINH=0)
•
Quick stop (QSP) is not activated
(MCTRL-QSP-OUT=0)
•
Manual operation is not ac tivated
(POS-MANUAL=0, C1280.B4=0)
C1284 HOMING-STATUS
0
0
1
5
10
11
20
25
not REF-OK
REF-OK
homing by prg
manu-ref-dig
manu-ref-1280
abs encoder
ext abs encod
Homing status
C1285
0 Trip Configuration - P01 (negative limit switch)
1 MONIT P01 4
4
Fail-QSP
2 MONIT P02 4
3 MONIT P04 4
4 MONIT P05 4
C1286
0
Trip
Configuration - P14 (following error 1)
1 MONIT P14 4
2
Warn
2 MONIT P15 3
4
Fail-QSP
C1287
0 Trip Configuration - P06 (no reference)
1 MONIT P06 4
4
Fail-QSP
C1288
0
2
Trip
Warn
Configuration - P12 (encoder limit)
1 MONIT P12 4
3
4
Off
Fail-QSP
C1289
0 Trip
Configuration P17, P18
1 MONIT P17 4
2
Warn
TP control
2 MONIT P18 2
3
4
Off
Fail-QSP
Range of representation limited/exceeded
(position limits, speeds)