Configuration
7-364
L
EDSVS9332P-D22 EN 3.0
Code ImportantPossible settings
No. SelectionLenzeLCD
C1290
0
2
Trip
Warn
Configuration - P16 (Sync error)
1 MONIT P16 4
3
4
Off
Fail-QSP
C1291
0 Trip Configuration - P07 (PS mode error)
1 MONIT P07 4
4
p
Fail-QSP
o
g
o
(
o
o
)
2 MONIT P08 4
3 MONIT P09 4
C1298 P18 DIAGNOSTIC
0
0
1
2
3
4
5
6
No P18
C1223
C1224
C1240
C1250
Vnorm
Anorm
P18 diagnostics
Display of the code which led to an internal
limitation.
C1299
0
0 {1 pcs} 65535
Actual state of piece counter
1 ACT. CNT
o
p
o
2 ACT. CNT
... ...
32 ACT. CNT
C1301 -214000 {0.0001 units} 214000
Input VTPOS p osition value
1 VTPOS-VALUE 0
p
p
o
o
2 VTPOS-VALUE 0
... ... ...
60 VTPOS-VALUE 0
C1302 0.01 {0.01 %vmax} 100
Input VTVEL speeds
1 VTVEL-VALUE 10
p
p
2 VTVEL-VALUE 20
... ... ...
10 VTVEL-VALUE 100
... ... ...
30 VTVEL-VALUE 100
C1303 0.01 {0.01 %amax} 100
Input of VTACC accelerations/decelerations
1 VTACC-VALUE 10
p
o
o
o
2 VTACC-VALUE 20
... ... ...
10 VTACC-VALUE 100
... ... ...
30 VTACC-VALUE 100
C1304 1 {1 pcs} 65535
Input VTPCS piece numbers
1 VTPCS-VALUE 1
p
p
... ... ...
30 VTPCS-VALUE 30
C1305 0 {0.001 s} 65535
Input VTTIME waiting times
1 VTTIME-VALUE 1
p
g
... ... ...
30 VTTIME-VALUE 30