Installation
4-38
L
EDSVS9332P-B EN 3.0
Resolver connection (X7)
In all configurations predefined under C0005, a resolver can be used as feedback system. An
adjustment is not necessary.
Note!
Use prefabricated Lenze system cables for the resolver connection.
Please contact Lenze before you use other resolvers.
Features:
2-pole resolver (V = 10 V, f = 4 kHz)
Resolver and resolver cable are monitored for open circuit (fault indication Sd2)
+ R E F
- R E F
+ C O S
- C O S
+ S I N
- S I N
R e s o l v e r
1
2
3
4
5
6
7
8
9
+ P T C
- P T C
P T C
X 7
9 p o l e S u b - D f e m a l e c o n n e c t o r
C a b l e l e n g t h m a x . 5 0 m
0 . 1 4 2 6
0 . 5 2 0
m m
2
A W G
Æ
Fig. 4-24 Resolver connection
Assignment of the female connector (X7)
Pin 1 2 3 4 5 6 7 8 9
Signal +Ref -Ref GND +COS -COS +SIN -SIN +PTC
( E 4-35)
-PTC