Gocator Web Interface • Scan Setup and Alignment • 105
Setting Description
than the gap interval, they will be merged into a single part.
Gap Length
Determines the minimum separation between objects on the Y axis. If parts are closer
than the gap interval, they will be merged into a single part.
Padding Width Determines the amount of extra data on the X axis from the surface surrounding the
detectedpart that will be included. This is mostly useful when processing part data with
third-party software such as HexSight, Halcon, etc.
Padding Length Determines the amount of extra data on the Y axis from the surface surrounding the
detectedpart that will be included. This is mostly useful when processing part data with
third-party software such as HexSight, Halcon, etc.
Min Area Determines the minimum area for a detected part. Set this value to a reasonable
minimum in order to filter out small objects or noise.
Max Part Length Determines the maximum length of the part object. When the object exceeds the
maximum length, it is automatically separated into two parts. This is useful to break a
long object into multiple sections and perform measurements on each section.
Frame of Reference Determines the coordinate reference for surface measurements.
Sensor
When Frame of Reference is set to Sensor, the sensor's frame of reference is used.
The way the sensor's frame of reference is defined changes depending on the surface
generation Type setting ( see on page 100 for more information):
l
When parts are segmented from a continuous surface (the surface generation Type
setting is set to Continuous), measurement values are relative to a Yorigin at the
center of the part (the same as for Part frame of reference; see below).
l
When parts are segmented from other types of surfaces (the surface generation Type
setting is set to Fixed Length, Variable Length, or Rotational), measurement
values are relative to a Yorigin at the center of the surface from which the part is
segmented.
The Surface Bounding Box GlobalXand GlobalYmeasurements (see Bounding Box on
page 173) are exceptions:regardless of the Frame of Reference setting, these
measurements produce the Sensor frame of reference values of the Part frame of
reference origin (which is the bounding box center), except for GlobalY when parts are
segmented from continuous surfaces. In this case the GlobalY value is the Y value relative
to the encoder zero position. These values can be used to locate Part frame of reference
measurements in a world space.
Part
When Frame of Reference is set to Part, all measurements except Bounding Box X and
Y are relative to the center of the bounding box of the part. For Bounding Box X and Y,
the measurement values are always relative to the sensor frame of reference (see
Bounding Box on page 173).
Edge Filtering
See Edge Filtering on the next page.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the LMI Technologies Gocator 2300 Series and is the answer not in the manual?

LMI Technologies Gocator 2300 Series Specifications

General IconGeneral
BrandLMI Technologies
ModelGocator 2300 Series
CategoryAccessories
LanguageEnglish

Related product manuals