Gocator 2300 & 2880 Series
Gocator Web Interface • System Management and Maintenance • 61
To enable/disable exposure multiplexing:
1. Go to the Manage page and click on the Sensor System category.
2. In the Layout section, check/uncheck the Exposure Multiplexing option.
This option is only displayed if a buddy is assigned.
Over Temperature Protection
Sensors equipped with a 3B-N laser by default will turn off the laser if the temperature exceeds the safe
operating range. You can override the setting by disabling the overheat protection.
Disabling the setting is not recommended. Disabling the overheat protection feature could lead
to premature laser failure if the sensor operates outside the specified temperature range.
To enable/disable overheat temperature protection:
1. Check/uncheck the Over Temperature Protection option.
2. Save the job file.
Networking
The Networking category on the Manage page provides network settings. Settings must be configured
to match the network to which the Gocator sensors are connected.