Gocator 2300 & 2880 Series
Protocols • ASCIIProtocol • 359
Message Format
Reply If no arguments are specified
OK or ERROR, <Error Message>
Examples:
Command:StationaryAlignment
Reply:OK
Command:StationaryAlignment
Reply:ERROR,ALIGNMENT FAILED
Moving Alignment
The Moving Alignment command performs an alignment based on the settings in the sensor's live job
file. A reply to the command is sent when the alignment has completed or failed. The command is timed
out if there has been no progress after one minute.
Message Format
Command MovingAlignment
Reply If no arguments are specified
OK or ERROR, <Error Message>
Formats
Examples:
Command:MovingAlignment
Reply:OK
Command:MovingAlignment
Reply:ERROR, ALIGNMENT FAILED
Clear Alignment
The Clear Alignment command clears the alignment record generated by the alignment process.
Message Format
Command ClearAlignment
Reply OK or ERROR, <Error Message>
Formats
Examples:
Command:ClearAlignment
Reply:OK