Gocator 2300 & 2880 Series
Protocols • Gocator Protocol • 303
Field Type Offset Description
count 32u 10 Number of state variables.
sensorState 32s 14 Sensor state
-1 – Conflict
0 – Ready
1 – Running
For more information on states, see Control Commands on page
299.
loginState 32s 18 Device login state
0 – No user
1 – Administrator
2 – Technician
alignmentReference 32s 22 Alignment reference
0 – Fixed
1 – Dynamic
alignmentState 32s 26 Alignment state
0 – Unaligned
1 – Aligned
recordingEnabled 32s 30 Whether or not recording is enabled
0 – Disabled
1 – Enabled
playbackSource 32s 34 Playback source
0 – Live data
1 – Recorded data
uptimeSec 32s 38 Uptime (whole seconds component)
uptimeMicrosec 32s 42 Uptime (remaining microseconds component)
playbackPos 32s 46 Playback position
playbackCount 32s 50 Playback frame count
autoStartEnabled 32s 54 Auto-start enable (boolean)
Log In/Out
The Log In/Out command is used to log in or out of a sensor.
Field Type Offset Description
length 32u 0 Command size including this field, in bytes.
id 16u 4 Command identifier (0x4003).
userType 32s 6 Defines the user type
0 – None (log out)
Command