EasyManua.ls Logo

LMI Technologies Gocator 2300 Series - Change Password; Set Buddy

LMI Technologies Gocator 2300 Series
431 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Gocator 2300 & 2880 Series
Protocols Gocator Protocol 304
Field Type Offset Description
1 Administrator
2 Technician
password[64] char 10
Password (required for log-in only).
Field Type Offset Description
length 32u 0 Reply size including this field, in bytes.
id 16u 4 Reply identifier (0x4003).
status 32s 6
Reply status. For a list of status codes, see Commands on page
295.
Reply
Change Password
The Change Password command is used to change log-in credentials for a user.
Field Type Offset Description
length 32u 0 Command size including this field, in bytes.
id 16u 4 Command identifier (0x4004).
user type 32s 6 Defines the user type
0 None (log out)
1 Administrator
2 Technician
password[64] char 10 New password.
Command
Field Type Offset Description
length 32u 0 Reply size including this field, in bytes.
id 16u 4 Reply identifier (0x4004).
status 32s 6
Reply status. For a list of status codes, see Commands on page
295.
Reply
Passwords can only be changed if a user is logged in as an administrator.
Set Buddy
The Set Buddy command is used to assign or unassign a Buddy sensor.
Field Type Offset Description
length 32u 0 Command size including this field, in bytes.
id 16u 4 Command identifier (0x4005).
buddyId 32u 6 Id of the sensor to acquire as buddy. Set to 0 to remove buddy.
Command

Table of Contents

Related product manuals