Gocator 2300 & 2880 Series
Protocols • Gocator Protocol • 322
Field Type Offset Description
length 32u 0 Command size including this field, in bytes.
id 16u 4 Command identifier (0x4526).
Command
Field Type Offset Description
length 32u 0 Reply size including this field, in bytes.
id 16u 4 Reply identifier (0x4526).
status 32s 6
Reply status. For a list of status codes, see Commands on page
295.
Reply
Clear Log
The Clear Log command clears the sensor's log.
Field Type Offset Description
length 32u 0 Command size including this field, in bytes.
id 16u 4 Command identifier (0x101D).
Command
Field Type Offset Description
length 32u 0 Reply size including this field, in bytes.
id 16u 4 Reply identifier (0x101D).
status 32s 6
Reply status. For a list of status codes, see Commands on page
295.
Reply
Simulate Unaligned
The Simulate Unaligned command simulates data before alignment transformation.
Field Type Offset Description
length 32u 0 Command size including this field, in bytes.
id 16u 4 Command identifier (0x452A).
Command
Field Type Offset Description
length 32u 0 Reply size including this field, in bytes.
id 16u 4 Reply identifier (0x452A).
status 32s 6
Reply status. For a list of status codes, see Commands on page
295.
Reply
Acquire
The Acquire command acquires a new scan.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the LMI Technologies Gocator 2300 Series and is the answer not in the manual?

LMI Technologies Gocator 2300 Series Specifications

General IconGeneral
BrandLMI Technologies
ModelGocator 2300 Series
CategoryAccessories
LanguageEnglish

Related product manuals