Gocator 2300 & 2880 Series
Protocols • Gocator Protocol • 322
Field Type Offset Description
length 32u 0 Command size including this field, in bytes.
id 16u 4 Command identifier (0x4526).
Command
Field Type Offset Description
length 32u 0 Reply size including this field, in bytes.
id 16u 4 Reply identifier (0x4526).
status 32s 6
Reply status. For a list of status codes, see Commands on page
295.
Reply
Clear Log
The Clear Log command clears the sensor's log.
Field Type Offset Description
length 32u 0 Command size including this field, in bytes.
id 16u 4 Command identifier (0x101D).
Command
Field Type Offset Description
length 32u 0 Reply size including this field, in bytes.
id 16u 4 Reply identifier (0x101D).
status 32s 6
Reply status. For a list of status codes, see Commands on page
295.
Reply
Simulate Unaligned
The Simulate Unaligned command simulates data before alignment transformation.
Field Type Offset Description
length 32u 0 Command size including this field, in bytes.
id 16u 4 Command identifier (0x452A).
Command
Field Type Offset Description
length 32u 0 Reply size including this field, in bytes.
id 16u 4 Reply identifier (0x452A).
status 32s 6
Reply status. For a list of status codes, see Commands on page
295.
Reply
Acquire
The Acquire command acquires a new scan.