Gocator 2300 & 2880 Series
Gocator Device Files Job Files 265
Element Type Description
HoldEnabled Boolean
Output hold enable state:
0 Disable
1 Enable
SmoothingEnabled Boolean
Smoothing enable state:
0 Disable
1 Enable
SmoothingWindow 32u Smoothing window.
Scale 64f Output scaling factor.
Offset 64f Output offset factor.
DecisionMin 64f Minimum decision threshold.
DecisionMax 64f Maximum decision threshold.
Percent
(Percentile measurement only)
64f Error percentile.
ProfilePanel
A ProfilePanelelement defines settings for a profile panel tool and one or more of its measurements.
Element Type Description
Name String Tool name.
Source 32s Profile source.
Anchor\X String (CSV) The X measurements (IDs) used for anchoring.
Anchor\X.options String (CSV) The X measurements (IDs) available for anchoring.
Anchor\Z String (CSV) The Z measurements (IDs) used for anchoring.
Anchor\Z.options String (CSV) The Z measurements (IDs) available for anchoring.
RefSide 32s Setting for reference side to use.
MaxGapWidth 64f Setting for maximum gap width (mm).
LeftEdge
ProfilePanelEdge
Element for left ede configuration.
RightEdge
ProfilePanelEdge
Element for right edge configuration.
Measurements\Gap
Gap measurement
Gap measurement.
Measurements\Flush
Flush measurement
Flush measurement.
ProfilePanel Child Elements
Element Type Description
EdgeType 32s
Edge type:
0 Tangent
1 Corner
MinDepth 64f Minimum depth.
ProfilePanelEdge