Gocator 2300 & 2880 Series
Gocator Device Files • Job Files • 268
Element Type Description
Enabled Boolean
Measurement enable state:
0 – Disable
1 – Enable
HoldEnabled Boolean
Output hold enable state:
0 – Disable
1 – Enable
SmoothingEnabled Boolean
Smoothing enable state:
0 – Disable
1 – Enable
SmoothingWindow 32u Smoothing window.
Scale 64f Output scaling factor.
Offset 64f Output offset factor.
DecisionMin 64f Minimum decision threshold.
DecisionMax 64f Maximum decision threshold.
ProfileStrip
A ProfileStrip element defines settings for a profile strip tool and one or more of its measurements.
The profile strip tool is dynamic, meaning that it can contain multiple measurements of the same type in
the Measurements element.
Element Type Description
Name String Tool name.
Source 32s Profile source.
Anchor\X String (CSV) The X measurements (IDs) used for anchoring.
Anchor\X.options String (CSV) The X measurements (IDs) available for anchoring.
Anchor\Z String (CSV) The Z measurements (IDs) used for anchoring.
Anchor\Z.options String (CSV) The Z measurements (IDs) available for anchoring.
BaseType 32s
Setting for the strip type:
0 – None
1 – Flat
LeftEdge Bitmask
Setting for the left edge conditions:
1 – Raising
2 – Falling
4 – Data End
8 – Void
RightEdge Bitmask
Setting for the right edge conditions:
1 – Raising
ProfileStrip Child Elements

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the LMI Technologies Gocator 2300 Series and is the answer not in the manual?

LMI Technologies Gocator 2300 Series Specifications

General IconGeneral
BrandLMI Technologies
ModelGocator 2300 Series
CategoryAccessories
LanguageEnglish

Related product manuals